Functions: penetrative protection, isolation
Application:
Earthwork dam, rock-fill dam, masonry dam and concrete dam; horizontal impervious blanket of embankment and dam front, vertical impervious barrier of foundation; tailing dam, dam body and reservoir region of sewage reservoir; construction cofferdam; canal, liquid bath (pit, coffin pit); waste storage; seepage control lining for subway, basement and tunnel; roadbed of speedway and railway; salting prevention of roadbed and other foundation; waterproofer of swelling soil and collapsible loess; roofing leak resistance
Products: Two-side seepage control membrane and one preventive geotextile; one-side seepage control membrane and preventive geotextile.
Width: 4-6m
Specification: membrane thickness 0.2mm-0.8mm; protective geotextile 100g/m2-800g/m2 (produced by our factory, conforming to the related national standard).
Table1 Basic Technological Requirement:
Serial number
|
Items
|
Indices
|
Allowance, %
|
|
1
|
Mass-area ratio, g/m2
|
According to design or contractual specifications
|
-10
|
|
2
|
Width, cm
|
According to design or contractual specifications
|
-1.0
|
|
3
|
Breaking strength 1),KN/m
|
According to design or contractual specifications
|
-5
|
Vertically and horizontally
|
4
|
Tearing extensibility %
|
Adherence to specification
|
30~100
|
Vertically and horizontally
|
5
|
Ripping strength 1), KN
|
According to design or contractual specifications
|
-8
|
Vertically and horizontally
|
6
|
CBR bursting strength, KN
|
According to design or contractual specifications
|
-5
|
|
7
|
Stripping strength 2), N/cm
|
6
|
Not below the standard
|
Vertically and horizontally
|
8
|
Resistance to hydrostatic pressure, Mpa
|
According to design or contractual specifications
|
Not below the standard
|
|
9
|
Permeability coefficient, cm/s
|
According to design or contractual specifications
|
Adherence to specification
|
|
1) For the strength requirements of common short-fiber needling nonwovens/polyethylene composite geomembrane, see Table 2
2) If the sample is tested hard to predict its stripping and not beyond the high strength base material and membrane material, it will be regarded as qualified one.